personal RCD device PRCD-S+

PCE

215.00

Available soon
estimated delivery time: 10-20 days

Onsite availability

personal RCD device PRCD-S+

personal RCD device PRCD-S+
PRCD-S+ inline 16A 230V 30mA IP55
16A 250V~; IΔN = 30mA
protection class IP55
housing grey / black / red
Earthing contact switches forward or lagging
Connection cross section: 1-2.5mm²
According to DIN VDE 0661
DGUV Information 203-006 (previously BGI / GUV-I 608)


The PCE PRCS - S + is a personal RCD device with built in test and safety functions. The PRCD - S + turns your extension lead into a personal protection device providing unrivalled safety, particularly in construction site applications.



The PRCD-S+ is an all-pole switching portable RCD circuit breaker with electronic fault evaluation for use on socket outlets with unknown protection measures, enabling persons and electrical equipment to safely draw current from a feed point.



Field of application:

As a portable residual current circuit breaker with a rated differential current of IΔn ≤ 30 mA or IΔn ≤ 10mA for alternating currents, pulsating DC residual currents and phase-controlled residual currents.



Function:

• The PRCD-S+ isolates all poles when tripped: In the event of a fault, the power supply via L and N is interrupted and the signal unit on the device lights up red. For additional safety, the PE conductor contact nevertheless remains closed until the fault has been cancelled. When the fault has been remedied, the PRCD-S+ can be activated again with the press of a button.



Every time the device is switched on, a routine check is performed to test the safe condition of the socket outlet.

The PE conductor circuit is switched on in advance and switched off with a delay

The integral undervoltage trip prevents automatic restarting after a power failure or an

interruption in the power supply.

The integral surge voltage protection detects 400 VAC and 220 VDC and does not allow

these to pass (a weak point occurs).

The PRCD-S+ cannot be switched on or switches itself off if:

° The PE conductor is interrupted.
° A fault voltage is measured on the PE conductor. ° A surge voltage or undervoltage is detected.
° A broken conductor is detected.

In the event of a fault voltage on the PE conductor, the protection device switches off the L and N conductor but maintains the connection to the PE conductor circuit.

The PRCD-S+ detects and protects in the case of the following faults:



Operation:

• N conductor interrupted
• External voltage on the PE conductor • Surge voltage
• Wiring errors

(L and PE conductor reversed)

Installation:

• PE conductor interrupted
• Undervoltage or voltage failure
• DC voltage
• Fault currents with rated values of

30 mA or 10 mA

Details

Product reviews (0)

This product has not been reviewed yet.

Rate product personal RCD device PRCD-S+

Onsite availability

You want to examine the product in advance or take it directly with you? Then come and see us. The product is currently in stock at the following locations :

Dispatch center
Ready for shipment at short notice
Hauptlager
Can be organized at short notice
Gebrauchtlager
Can be organized at short notice
Außenlager
Can be organized at short notice

Downloads

Article of the same product series

Customers also bought

Additional product data

Material number
967011355
Product state:
New
Categories:
miscellaneous accessories